Channels

 

Special Offers & Promotions

 

 

Latest News

 

 

View Channel

New Products

 

 

View Channel

Video Presentations

 

 

View Channel

Separation Science

 

 

View Channel

Microscopy & Image Analysis

 

 

View Channel

Laboratory Automation & IT Solutions

 

 

View Channel

 

Linkam Launches the CMS196M for Enhanced Cryo-Correlative Microscopy with Greatly Improved Work Flow

publication date: Feb 23, 2017
 | 
author/source: Linkam Scientific Instruments Limited

Market leaders in temperature controlled microscopy and established manufacturers of advanced freeze drying microscopes, Linkam Scientific Instruments, announce the launch of the CMS196M for enhanced cryo-correlative microscopy with greatly improved work flow.

stage for cryo-correlative microscopyLinkam has been developing cryo stages for correlative microscopy for many years and continues to be at the forefront of cryo-correlative microscopy with the latest update of their LINK software for the CMS196M, providing improved imaging capabilities and the new liquid nitrogen autofill system providing longer run times.

Cryo-correlative microscopy has become an established technique in recent years. It brings together the strengths of both electron and light (fluorescence) microscopy. Electron microscopy (EM) provides structural information at very high resolution. However, it can give only restricted insight into biological and chemical processes due to limitations in staining and sample preparation processes. On the other hand, fluorescence microscopy is an extremely sensitive technique to detect biological, chemical and genetic processes as well as events inside living cells.

Cryo-CLEM brings it all together: combining the individual advantages from both fluorescence and EM by imaging the same sample location with both techniques and superimposing the complementary information.

For biological samples to be compatible with the vacuum conditions found in EM and preserve the structural detail, samples are embedded in vitrified “glass like” ice and need to be kept below -140 °C. Any contact with moisture contained in the air has to be avoided since ice crystals would form immediately and contaminate the sample. Under cryo conditions, the fluorescence signals providing structural detail is preserved and photo bleaching is significantly reduced.

LINK software for the CMS196 provides complete control and monitoring of the system as well as fully-automated tiled image capture. The integrated, encoded, high resolution motorised XY stage gives the ability to capture an image of the entire EM grid at full resolution. Shown below, the system produces a single image of the EM grid that can then be used to navigate the sample and save co-ordinates of areas of interest making it easy to image the same area when the sample is transferred to the EM. In addition, LINK can now be supplied with an extremely cost effective, high sensitivity monochrome camera ideal for low light fluorescence imaging.


more about linkam


more news from linkam


 



 

Subscribe to any of our newsletters for the latest on new laboratory products, industry news, case studies and much more!

Newsletters from Lab Bulletin

 

Request your free copies HERE

 

 

 

Popular this Month

Top 10 most popular articles this month

 

 

Today's Picks

 


 

Looking for a Supplier?

Search by company or by product

 


Company Name:

Product:


 

 

 

 

Please note Lab Bulletin does not sell, supply any of the products featured on this website. If you have an enquiry, please use the contact form below the article or company profile and we will send your request to the supplier so that they can contact you directly.

Lab Bulletin is published by newleaf marketing communications ltd.


 

Media Partners

 

Exhibitions & Events